包米勒高性能伺服驅(qū)動器維修:2013:Timeout quick discharge超時快速放電。The active mains rectifier unit calculates the discharging time from the maximum discharging resistor (see Instruction Manual) and the maximum DC link capacity according to the relation:電整流器單元根據(jù)以下關(guān)系式計算最大放電電阻器的放電時間(請參閱說明書)和最大直流鏈路容量:
If the discharging is triggered, the DC link is discharged always for at least 10 s via the discharging resistor. 如果觸發(fā)放電,則直流鏈路總是通過放電電阻器放電至少10 s。
南通鮑米勒伺服驅(qū)動器維修服務(wù):
If the DC link voltage is greater than 20 V after 10 s discharging time, then it is checked whether the calculated discharging time is greater than the so far elapsed discharging time of 10 s. 如果DC鏈路電壓在10s放電時間后大于20V,則檢查計算出的放電時間是否大于迄今為止經(jīng)過的10s的放電時間。
If this is not the case, the error is triggered at once.
如果不是這種情況,則會立即觸發(fā)錯誤。
If the calculated discharging time is greater than 10 s and if the DC link voltage is greater than 20 V after the discharging time, then the error is triggered also in this case.如果計算的放電時間大于10s,并且如果DC鏈路電壓在放電時間之后大于20V,則在這種情況下也觸發(fā)誤差。
Possible causes: The chopper resistor is not connected or was selected too great. Possibly the DC link capacity is greater than specified (see Operating Instructions BM5000 (5.09021)).可能的原因:斬波電阻器未連接或選擇得太大。直流鏈路容量可能大于規(guī)定值(請參閱操作說明BM5000(5.09021))。